Aptamer 学术简报 — biosensor — 2026-06-05
自动生成 by RBTX Aptamer Tracker v0.1。 子主题 biosensor:近 14 天 141 篇命中(aptamer 池 234 篇)。
评分公式:composite = 0.45×log(IF) + 0.35×log(cites_velocity) + 0.10×social + 0.10×recency_bonus;满分 100。
#1 [25.5] A dual-mode electrochemiluminescence/SERS biosensor for B-type natriuretic peptide based on a T7-CRISPR/Cas13a cascade and a CsPbBr(3)@PDA@Au perovskite interface.
- Journal: Biosensors & bioelectronics (IF 10.7)
- Date: 2026-06-01 · Citations: 3 · 0.75 cites/day
- Authors: Li Y, Ren H, Wu R et al. (10 authors)
- DOI: 10.1016/j.bios.2026.118484 · PMID: 41671930
- Score components: IF 10.7 · velocity 34.3 · recency 86.7
B-type natriuretic peptide (BNP) is an important biomarker for cardiovascular diseases, motivating sensitive and robust quantification in complex matrices. Here we report a single-electrode, anti-correlated dual-mode electrochemiluminescence/surface-enhanced Raman scattering (ECL/SERS) biosensor that couples split-aptamer recognition with a solu...
#2 [20.7] Engineered dual-fluorescence functional nucleic acid-based CRISPR/Cas12a biosensor for label-free ratiometric detection of site-specific DNA methylation.
- Journal: Synthetic and systems biotechnology (IF ?)
- Date: 2026-06-01 · Citations: 3 · 0.75 cites/day
- Authors: Tian W, Yu S, Zhang K et al. (6 authors)
- DOI: 10.1016/j.synbio.2025.11.003 · PMID: 41321596
- Score components: velocity 34.3 · recency 86.7
The CRISPR/Cas12a system holds significant promise for biomedical applications. Nevertheless, the commonly used reporter, fluorophore-quencher-labeled substrates, is hindered by labor-intensive synthesis procedures and high costs, while also relying on a single-photon method and being vulnerable to environmental interference. Herein, a label-fre...
#3 [20.6] Advancing point-of-care diagnostics: Engineering and enhancing sensitivity and specificity in nanoparticle-based lateral flow assays for rapid disease detection.
- Journal: Talanta (IF 6.1)
- Date: 2026-06-01 · Citations: 1 · 0.25 cites/day
- Authors: Lala A, Kalyani T, Kotal H et al. (4 authors)
- DOI: 10.1016/j.talanta.2026.129450 · PMID: 41637804
- Score components: IF 8.5 · velocity 23.2 · recency 86.7
Lateral flow assay (LFA) is the most widely used point-of-care (PoC) diagnostic tools due to their simplicity, rapid turnaround, portability, and low cost. Despite their extensive adoption in clinical diagnostics, food safety, and environmental monitoring, conventional LFA remain limited by inadequate sensitivity, poor quantification, and restri...
#4 [20.6] Switch-type photoelectrochemical aptasensor for microplastics and nanoplastics detection based on two-dimensional organic-inorganic heterojunction.
- Journal: Talanta (IF 6.1)
- Date: 2026-06-01 · Citations: 1 · 0.25 cites/day
- Authors: Bai X, Zhang G, Tang C et al. (8 authors)
- DOI: 10.1016/j.talanta.2026.129467 · PMID: 41650923
- Score components: IF 8.5 · velocity 23.2 · recency 86.7
Microplastics and nanoplastics (MNPs) as emerging pollutants present substantial risks to both the environment and human health. Developing highly sensitive methods to rapidly identify and detect low concentrations of MNPs in complex systems remains a considerable challenge. Here, an "off-on" switch-type photoelectrochemical (PEC) aptasensor was...
#5 [19.2] An electrochemical biosensing platform based on α‑iron trioxide/ferriferrous oxide magnetic nanocomposites for early diagnosis of hepatocellular carcinoma.
- Journal: Bioelectrochemistry (Amsterdam, Netherlands) (IF ?)
- Date: 2026-06-01 · Citations: 2 · 0.50 cites/day
- Authors: Zhang H, Ouyang H, Zhou Z et al. (6 authors)
- DOI: 10.1016/j.bioelechem.2025.109203 · PMID: 41406518
- Score components: velocity 30.1 · recency 86.7
The detection of biologically active proteins in complex biological matrices such as serum remains challenging. To enhance the sensitivity and accuracy of detecting the hepatocellular carcinoma biomarker stress-induced phosphoprotein 1 (STIP1), we proposed a label-free "Turn-off" electrochemical aptamer-based biosensing platform without requirin...
#6 [19.2] Gold nanoparticle-modified graphene oxide electrochemical aptasensor for ultrasensitive detection of interferon gamma in kidney transplants.
- Journal: Bioelectrochemistry (Amsterdam, Netherlands) (IF ?)
- Date: 2026-06-01 · Citations: 2 · 0.50 cites/day
- Authors: Hosseini N, Nakhjavani SA, Ardalan M et al. (6 authors)
- DOI: 10.1016/j.bioelechem.2025.109207 · PMID: 41455373
- Score components: velocity 30.1 · recency 86.7
The early and accurate detection of interferon gamma (IFN-γ), a key cytokine in acute cellular rejection following kidney transplantation, is essential for effective immunosuppressive management. Current methods often lack the sensitivity, speed, or simplicity for routine clinical immunomonitoring. Here, we developed a novel electrochemical apta...
#7 [14.8] Tracing Tumor-Derived Extracellular Vesicle Matrix Metalloproteinase 14 Using Dual-Target Orthogonal Barcoding-Based Microscale Thermophoretic Assays.
- Journal: ACS nano (IF 15.8)
- Date: 2026-06-03 · Citations: 0
- Authors: Chen A, Wang R, Zou Y et al. (11 authors)
- DOI: 10.1021/acsnano.6c07750 · PMID: 42234976
- Score components: IF 12.2 · recency 93.3
Longitudinal monitoring of tumor progression and metastasis provides significant benefits to improve the treatment outcome of breast cancer. Matrix metalloproteinase 14 (MMP14) on extracellular vesicles (EVs) is highly relevant to tumor invasiveness, yet the sensitivity and specificity of detection are hindered by tremendous amounts of normal EV...
#8 [14.0] An immune-inspired intelligent aptasensor with broad detection capability.
- Journal: Trends in biotechnology (IF 14.3)
- Date: 2026-06-01 · Citations: 0
- Authors: Li N, Wei K, Zhang Y et al. (8 authors)
- DOI: 10.1016/j.tibtech.2025.12.016 · PMID: 41620364
- Score components: IF 11.8 · recency 86.7
Biosensors, particularly aptasensors, play a pivotal role in rapid diagnostics, but their practical performance is limited by suboptimal aptamers and conventional aptamer-material combination-based approaches. To overcome the limitations, we drew inspiration from living systems by pioneering an immune-inspired biomimetic strategy that harnesses ...
#9 [13.7] A Portable Dual-Mode Aptasensor for Rapid Detection of Influenza A Hemagglutinin.
- Journal: ACS sensors (IF 8.2)
- Date: 2026-06-03 · Citations: 0
- Authors: Koneru A, Barui AK, Cantemir M et al. (5 authors)
- DOI: 10.1021/acssensors.5c02025 · PMID: 42234406
- Score components: IF 9.6 · recency 93.3
We report a highly portable dual modality aptasensing platform for the detection of surface glycoprotein, hemagglutinin (HA), of the influenza A virus. The sensing device consists of a colorimetric detection component composed of a microfluidic paper-based analytical device (μPAD) having four analyte testing areas, as well as a flexible, miniatu...
#10 [13.7] Unlocking Self-Luminescence of Pyrene-Based Metal-Organic Gel for Sensitive Electrochemiluminescence Assay of Microplastics.
- Journal: Analytical chemistry (IF 6.7)
- Date: 2026-06-04 · Citations: 0
- Authors: Yang G, Li Z, Hu Q et al. (6 authors)
- DOI: 10.1021/acs.analchem.6c02352 · PMID: 42241521
- Score components: IF 8.9 · recency 96.7
Pyrene (Py), an archetypal electrochemiluminescence (ECL) luminophore, suffers from inherent aggregation-caused quenching (ACQ) stemming from its planar π-conjugated structure and consequent intermolecular π-π stacking, severely restricting its practical utility. Herein, a gel confinement-induced emission enhancement (GCIEE) strategy is proposed...
Methodology
- 数据源:PubMed (esearch + esummary), OpenAlex (concept C2776201186 + DOI 反查 citations), bioRxiv (preprints)
- 去重:按 DOI 跨源合并
- IF:硬编码 top 50 期刊 JCR 2024 IF(
config.JOURNAL_IF) - Citation velocity:OpenAlex
cited_by_count/ 发表天数 - Social:Reddit r/science + r/biotech + HN(DOI/title 关键词搜)
- 窗口:近 14 天发表;超出 30 天 recency_bonus = 0
- 每天:建议 8-9am 跑
python run.py collect && python run.py score && python run.py report